2026 NYJC H3 Chem 9813 P1 Insert
Uploaded by Kozak327 · 10 November 2026
Preview
Text from the first pagesH3 Chemistry 9813/01 NYJC J2/2026 PX [Turn Over NANYANG JUNIOR COLLEGE JC 2 PRELIMINARY EXAMINATION Higher 3 CHEMISTRY 9813/01 Paper 1 22 September 2026 INSERT Candidates answer Secti2 hours 30 minutes READ THESE INSTRUCTIONS FIRST This insert contains information for Question 1. Do not write your answers on the insert. 2 3 4 5 This document consists of 3 printed pages and 1 blank page. H
2 H3 Chemistry 9813/01 NYJC J2/2026 PX Information for Question 1 Refrigeration is indispensable to modern society, yet the dominant vapour compression systems rely on environmentally harmful chlorofluorocarbons (CFCs) , hydrochlorofluorocarbons (HCFCs) , and hydrofluorocarbons (HFCs) refrigerants with high global warming potential. The 100-year global warming potential, GWP100, of a gas refers to the total contribution to global warming in a 100-year time horizon resulting from the emission of one unit of that gas relative to one unit of the reference gas, CO2, which is has a value of 1. Ozone Depletion Potential , ODP, is defined as a numerical value that indicates the amount of ozone depletion caused by a substance, expressed as the ratio of its impact on ozone compared to that of a similar mass of CFCl3, which has a value of 1. Table 1.1 lists some properties of common refrigerants with an evaporation temperature of −10 °C. Table 1.1 refrigerant GWP100 ODP vapour density, »g / g m−3 latent heat of vaporisation, Lv / J g−1 code compound R717 NH3 0 0 2310 1297 R744 CO2 1 0 65000 230 R600a (CH3)3CH 4 0 3100 363 R12 CF2Cl2 10900 1 13040 156 R22 CHF2Cl 1810 0.055 15340 213 R32 CH2F2 675 0 16380 315 Abstract 1 describes a method of refrigeration using the vapour compression system. Abstract 2 describes a method of refrigeration using the solid-state caloric system. Abstract 1 (Science, 2020, 370, 791−796) Vapour compression refrigeration systems exploit two fundamental properties of all liquids: (i) The boiling temperature varies with pressure, and (ii) a change in phase (liquid boiling to a vapour and condensing back to a liquid) is accompanied by the absorption or release of heat. Fig. 1.1 shows the vapour compression cycle. Fig. 1.1 step 1 step 2 step 3 step 4
3 H3 Chemistry 9813/01 NYJC J2/2026 PX Alternative to CFCs, HCFCs, and HFCs Hydrofluoroolefins (HFOs) were identified as a promising replacement. “Olefin” refers to a class of organic chemicals with a double bond between carbon atoms. The double bond is highly reactive to naturally occurring hydroxyl radicals in the atmosphere, resulting in atmospheric lifetimes of days to weeks for the HFOs, compared with years to decades for the HFCs. Thus, the GWP100 for most HFOs are under 1. Abstract 2 (Nature, 2026, 649, 1180−1185) Recently, a team of researchers reported an extreme barocaloric effect (BCE) at dissolution using an aqueous solution of ammonium thiocyanate, NH4SCN. This system harnesses the endothermic nature of salt dissolution and tunes it reversibly using external pressure. Fig. 1.2 shows the refrigeration mechanism operating on a four-step Carnot-like thermodynamic cycle. Fig. 1.2 1 → 2 (Adiabatic Compression): External pressure is applied rapidly to a saturated aqueous solution of NH4SCN with the circulating pump turned off, causing the salt to precipitate out. This process is exothermic. 2 → 3 (Isothermal Heat Rejection): With the pump turned on, pressure is adjusted to complete precipitation while heat is continuously rejected to the ambient environment. 3 → 4 (Adiabatic Decompression): The pump is turned off, and the external pressure is rapidly removed. The sudden depressurisation shifts the equilibrium back to favour dissolution. This endothermic dissolving process drives an instantaneous in-situ temperature drop. 4 → 1 (Isothermal Cooling): The pump is turned on, allowing the self-circulating solution to absorb heat directly from the cooling target as the remaining salt dissolves, completing the cycle. Pressure-tuned precipitation and dissolution To monitor the structural transitions in real time, in-situ pressure-dependent infra-red (IR) spectroscopy was performed on a 60 wt% NH4SCN solution at 293 K. At 10 MPa, a single absorption peak at 2240 cm−1 is observed. At 260 MPa, two distinct absorption peaks were observed. One remaining at a 2240 cm−1 and a new absorption peak emerging at 2215 cm −1. Upon dropping the pressure to 220 MPa, the absorption peak at 2215 cm−1 vanishes completely.
4 H3 Chemistry 9813/01 NYJC J2/2026 PX BLANK PAGE Copyright Acknowledgements Question 1 Abstract 1 © Mark O. McLinden et al. (2020) Science, 370, 791−796. Abstract 2 © Zhang, K., Liu, Y., Gao, Y. et al. (2026) Nature, 649, 1180−1185.
Content continues in the PDF. Download PDF
